An inexpensive and rapid method for removal of multiple stri
A 29-year-old male with a history of right tibial shaft and lateral malleolus fractures following a fall injury underwent open reduction and internal fixation with a locking plate for the fibula fracture and minimally invasive percutaneous osteosynthesis for the tibial shaft fracture at another hospital. Postoperatively, the patient was followed up at our hospital for 1 year due to residential issues, and the removal of the plate was scheduled after confirmation of bone union. According to the previous hospital’s medical records, a 9-hole locking plate (APIS®, Gwangju, Republic of Korea) was used for the distal tibia, with three 5.0-mm locking screws for proximal fixation and six 3.5-mm locking screws for distal fixation.

Under spinal anesthesia, a plate removal surgery was performed, following which the fibular plate was easily removed. However, five of the six distal locking screws were damaged, and they could not be removed with a screwdriver. This situation was explained to the patient during the operation, and we could confirm that the patient wanted to remove the plate irrespective of the amount of time required. At the time, a tourniquet was used for approximately 1 h, and screw removal was attempted using a conical extraction screw, but only one of the six screws could be removed.

Previously proposed techniques requiring additional skin incisions were not considered because there were multiple damaged screws that could not be removed, these techniques would require extended amount of time for removal, and the surrounding soft tissues could be damaged. Hence, we decided to use a screw extractor (IRWIN®, Huntersville, NC, USA), a non-medical instrument, following sterilization with ethylene oxide. In brief, 6-mm drill bit of the extractor was used, four screw heads were drilled, the locking screws and locking plate were separated, and the plate was removed. Of the remaining four screws, one was removed using a vice grip; the remaining three screws could not be removed with the vice grip owing to a short extruded portion. A hollow reamer could not be used because the three screws were adjacent to each other and the reamer could cause a large bone defect; hence, we created sufficient space around the screws by forming small holes around them with a 1.8-mm K-wire, following which all screws could be removed using the vice grip.

After saline irrigation, debridement of the soft tissues contaminated with metal debris was performed. The sizes of the metal debris were found to be relatively large, which facilitated easier debris removal. With 2-h use of a tourniquet, all implants could be removed and the skin could be closed. Postoperatively, no complications were noted during physical and radiological examinations. Remarkably, no problems were noted at the final outpatient visit at 3 months after discharge; therefore, follow-up was terminated. The patient had not visited an outpatient clinic for more than a year since the last follow-up, thus we thought that he had no specific complications including infection and re-fracture.

Source: International Journal of Surgery case reports

Read more: https://pxmd.co/ODRaZ
P●●●h P●●●●r and 3 others like this
Like
Comment
Share
Dr. K●●●r A●●●●●v
Dr. K●●●r A●●●●●v Internal Medicine
Wao, awesoome performance
Apr 14, 2019Like1