Can calculation of energy expenditure based on CO2 measureme
Now open: Certificate Course in Management of Covid-19 by Govt. Of Gujarat and PlexusMDKnow more...Now open: Certificate Course in Management of Covid-19 by Govt. Of Gujarat and PlexusMDKnow more...
Abstract

Background :
Methods to calculate energy expenditure (EE) based on CO2 measurements (EEVCO2) have been proposed as a surrogate to indirect calorimetry. This study aimed at evaluating whether EEVCO2 could be considered as an alternative to EE measured by indirect calorimetry.

Methods :
Indirect calorimetry measurements conducted for clinical purposes on 278 mechanically ventilated ICU patients were retrospectively analyzed. EEVCO2 was calculated by a converted Weir’s equation using CO2 consumption (VCO2) measured by indirect calorimetry and assumed respiratory quotients (RQ): 0.85 (EEVCO2_0.85) and food quotient (FQ; EEVCO2_FQ). Mean calculated EEVCO2 and measured EE were compared by paired t test. Accuracy of EEVCO2 was evaluated according to the clinically relevant standard of 5% accuracy rate to the measured EE, and the more general standard of 10% accuracy rate. The effects of the timing of measurement (before or after the 7th ICU day) and energy provision rates (<90 or ?90% of EE) on 5% accuracy rates were also analyzed (chi-square tests)........

https://ccforum.biomedcentral.com/articles/10.1186/s13054-016-1595-8